Implant arthroplasties of the elbow are designated as
constrained, semi-constrained, and unconstrained. The differentiation is based
on the rigidity of the fixation of the humeral component to the ulnar
component. Constrained prostheses are used when bone loss is extensive and soft
tissue stability is absent. This prosthesis design has a tendency to loosen and
break and is used only in salvage situations.
The unconstrained prostheses are designed to resurface
articulating interfaces and consist of metal and high-density polyethylene.
These prostheses require normal intact ligaments and anterior capsule, as well
as appropriate static alignment.
The semiconstrained prostheses have a hinge design yet possess
the ability to provide varus and valgus laxity to dissipate joint reactive
forces.
Early hinge-designed elbow prostheses required extensive soft
tissue and bony excision. These joints were rigid and did not provide for force
dissipation at the elbow. Results were disappointing and today this design is
rarely used. Reported complications of semiconstrained elbow arthroplasty
include nerve paresthesias, wound problems, and fracture of either the humerus
or ulna. The most common complication requiring revision in semiconstrained
prostheses is loosening of the humeral component (7%). In unconstrained
prostheses, the most common complication requiring revision is elbow
instability (9%). Overall, the complication rates related to total elbow
arthroplasty have generally been reported around 30% to 40%. In an attempt to
minimize complication rates, Morrey et al.1 recommend a straight incision
medial to the tip of the olecranon. Also, detachment of the triceps from the
olecranon without division of the tendon, simultaneous transposition of the
ulnar nerve, drainage of the wound with a suction drain, and initial splinting
in full extension.
- Morrey BF, Bryan RS, Dobyns JH, Linscheid RL. Total elbow
arthroplasty: A 5-year experience at the Mayo Clinic, J Bone Joint Surg. 1981;
63-A: 1050.