Hyperguides

Orthopaedics / Adult orthopaedics

Metal-on-Metal Total Hip Replacement

Lawrence D. Dorr, MD Reprinted with permission from Dorr LD. Metal-on-metal: All things bright and beautiful! Orthopedics. 2002; 25:931.
Article

Metasul (Sulzer Orthopedics Ltd, Baar, Switzerland) has been used for 13 years in Europe. Presently, more than 150,000 Metasul articulation surfaces are implanted worldwide. With changes that have occurred in polyethylene during the 1990s, Metasul is now the second oldest articulation surface used for patients.

Direct compression molded to polyethylene has longer service. I have 10 years of experience, and the results of my first series using the cemented Weber cup (Sulzer) and APR stem (Sulzer) have the longest follow-up of 10 years, and the mechanical failure rate remains 1.2% with one cup loosening and no stem loosening.1

Sulzer (Austin, Tex) conducted an investigational device exemption (IDE) study in the United States of the Metasul articulation surface using a noncemented stem group and a cemented stem group. Control groups were comprised of patients who received a ceramic-on-polyethylene articulation surface. Although the Metasul study group had more male patients, the trend for fixation and clinical scores favors Metasul over the polyethylene-ceramic articulation study group.

Impingement has been a concern of metal-on-metal articulation in the past, but it has not been observed as a mechanism of failure to date. The surgeon should mate the head and the cup (i.e., no more than 50% of the femoral head is uncovered throughout the entire range of motion of the hip) to avoid impingement.

The controversies with Metasul relate to increased metal ions. In Europe, Hans Willert reported a 0.5% prevalence of hypersensitivity to metal-on-metal (personal communication, January 2001). This has not occurred in the 400 patients who participated in the IDE study. There also is a theoretical concern of cancer. The 20-year studies from Scandinavia (particularly Finland) have not found any positive correlation to cancer.2 There was some increase in leukemia-type cancers, but this was not statistically significant. In our cemented Weber group, 3 of 12 deaths have been from cancer, but they were age-related.1 Two deaths were related to prostate cancer. In the modular group, one elderly patient died from leukemia. The occurrence of cancer in our patients is not outside the standard mortality rate for the age group.

One advantage of Metasul is a low incidence of osteolysis. Osteolysis in the cemented cup and the modular cup series has been better than that observed with standard polyethylene acetabular components.

The Metasul metal-on-metal articulation has a polyethylene backing. There is some creep of polyethylene backing (0.03 mm) at 1 year, which then remains stable. The advantage of the metal-on-metal articulation is that, although some creep may take a polyethylene liner out of round, with metal-on-metal, the bearing surface remains congruent. The only osteolysis we observed was calcar resorption. In the cemented monoblock Weber cup, 1 (2%) of 50 patients showed calcar resorption. In the modular group, 4 (9%) of 46 patients showed calcar resorption. It is unknown whether there is an increased calcar resorption in the modular series because it is modular with increased debris from the modularity or because this group is younger and more active.

Patient satisfaction has been high with Metasul total hip replacement (THR). For the cemented cup and modular cup series, more than 90% of patients graded their results as excellent or very good.1 There is no clinical difference in the IDE series of modular Metasul articulation versus modular ceramic-on-polyethylene articulations for patient results.

To date, Metasul has been used clinically for 13 years with 150,000 Metasul articulations implanted in THRs. Our implant autopsy retrieval has confirmed a low rate of wear of 3 µm to 5 µm per year after an initial run-in wear of 25 µm. If we agree that a perfect hip replacement has 90% survival at 25 years, 95% patient satisfaction, linear wear less than 0.06 mm per year, and osteolysis less than 25% at 25 years, we are within reach of these goals. Therefore, we continue to use Metasul articulations in patients younger than 75 years old.

References

  1. Dorr LD, Wan Z, Longjohn DB, Murken R. Total hip arthroplasty with use of Metasul metal-on-metal articulation. Four to seven-year results. J Bone Joint Surg Am. 2000; 82:789-798.


  2. Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB. Cancer risk after metal on metal and polyethylene-on-metal total hip arthroplasty. Clin Orthop. 1996; 329(suppl):S280-S289.