Preoperative planning is important in revision total knee replacement (TKR). Revision TKR can be a challenging experience for all involved. Multiple implant options include cemented and cementless primary and revision tibial and femoral components, with or without posterior cruciate ligament (PCL) retention. Some cases may require additional varus/valgus constraint or even a rotating hinge. Femoral and tibial spacers may also be needed. The last thing a surgeon wants is to be in the middle of a revision TKR surgery and not have what he or she needs.
If you ask an implant representative, for example, to "bring everything, just in case," you will get about 23 pans of instruments, 24 bins of implants composed of 347 boxes of sterile implants, and chaos. To simplify the situation, preoperative planning should be done to determine exactly what implants are needed ahead of time to minimize the chaos.
Cemented components are used for most revision surgeries because most revision knee systems allow for a more conservative cementing of just the metaphyseal portions and use of press-fit stems. Occasionally, a young patient with good bone quality might achieve a successful result with noncemented fixation, but this situation is rare. Of 318 revision TKRs I performed between 1987 and 2000, 95% were cemented.
My goal in revision TKR is to use the least constrained implants as possible that will achieve stability. Using more constraint than is required will subject the implant-cement-bone interfaces to unnecessarily increased stresses that may cause earlier loosening. Varus/valgus constrained implants can still be unstable if the flexion/extension spaces are not adequately tensioned and balanced.
Preoperative physical examination and radiographs will help determine the status of the collateral ligaments. Scarring at surgery makes determination of PCL integrity difficult, so it is preferable to substitute for the PCL if one is unsure of its function.
If the lateral collateral ligament is absent, varus/valgus constrained implants are preferred. Sufficient lateral soft-tissue scarring usually occurs while the central post provides internal support. With medial collateral ligament (MCL) insufficiency, medial soft-tissue support usually is inadequate to prevent severe post wear or breakage over time. For a younger patient, varus/valgus constrained implants with a MCL reconstruction using an Achilles tendon allograft is recommended. A rotating hinge implant is preferred for the older patient without a MCL.
Primary implants can be used in some revision TKRs if there is minimal bone loss and good bone quality. Use of a primary femoral component with distal femoral bone loss will move the joint line proximal, resulting in either extension instability or loss of flexion. Most revision TKRs have some distal and posterior femoral bone loss. Use of a revision femoral component with distal and posterior femoral build-up makes reestablishing the joint line easier and may negate the need for femoral spacers.
Correct joint line positioning is important. If one uses a revision femoral component that is thicker than the distal femoral bone loss present, the joint line is moved distally, resulting in either flexion instability or lack of knee extension. Correct position of the joint line is difficult to determine intraoperatively because of the lack of normal distal and posterior femoral surfaces as landmarks. The correct joint line position is dependent on the femoral component position.
Intraoperatively, the flexion/extension spaces can be balanced by cutting off more and more of the distal femur or adding spacers to the femoral component distally until the extension space equals the flexion space. This technique relies on intact and balanced collateral ligaments. This does not guarantee the joint line is in the correct position. The flexion and extension spaces can be balanced with a smaller femoral component, but midflexion instability and patellar baja will occur because the joint line will be too proximal.
Preoperative planning is used to determine the correct joint line position and the correct femoral component anteroposterior size. This will simplify the surgery by reducing the number of times the distal femur and chamber cuts are made to balance the knee. The measurement from the joint line to the medial femoral epicondylar ridge on the normal knee is placed on the abnormal radiograph to show where the joint line position on the revision side is relative to the existing femoral component.
In summary, preoperative physical examination and radiographs are used to determine the status of the PCL and collateral ligaments, so components with the appropriate constraint are available. Radiographs will also show if spacers or bone graft will be needed. Time spent on preoperative planning will minimize an excessive number of instruments and implants, which will only add confusion to the surgery.
Preoperative planning is needed to determine the correct size femoral component and the joint line position. Preoperative planning will help assure a stable revision knee for the patient and simplify the surgery for the surgeon, operating room team, and implant representative.