Periprosthetic fractures about total knee arthoplasty (TKA) are relatively rare (0.5% to 3%). The most common periprosthetic fracture about TKA is the supracondylar fracture. It is an infrequent injury; however, the complication rate in treating this injury is high. The nonunion rate is reported by some authors to be as high as 20%. Nonunion and loss of motion are frequent.
One risk factor for developing this fracture is osteopenia, which occurs about the knee. Anterior notching of the femur during primary TKA creates a stress riser in the supracondylar region and is a common cause of periprosthetic supracondylar fracture. This notch will weaken the femur by 45% in torsion and 20% in bending. Supracondylar notching has been reported in 15% to 20% of primary TKAs even in experienced hands and has resulted in an approximately 1.5% incidence of fracture. If an anterior notch is noted, this stress riser must be bypassed with a stemmed prosthesis. After supracondylar fracture is diagnosed, treatment choices include: 1) conservative treatment, 2) right angle plating, 3) intramedullary rodding, and 4) revision TKA.
Articles on closed treatment report overall 57% satisfactory results whereas open treatment has reported satisfactory results up to 70%.
In a large meta analysis by Chen, closed treatment in a completely undisplaced fracture achieved 83% satisfactory results whereas open treatment in displaced fractures achieved approximately 65% satisfactory results.
Unfortunately, the patient with a minimally comminuted nondisplaced fracture and good bone stock is rare; however, if this occurs the patient can be treated with a closed technique.
In a displaced supracondylar fracture when the prosthesis is well fixed, the fracture should be fixed. The options for fixing supracondylar fractures are a right angle plate device that consists of a blade plate, a right angle compression screw, or fixed angle LISS plate.
Indirect reduction is used to reduce the fracture. Solid fixation is important in distal and proximal fragments. In the distal fragment, fixation must be moved slightly proximal to avoid the pegs or box of a posterior stabilized knee. Fixation lag or locking screws should be at right angles to the slope of the lateral aspect of the femoral condyle and should start in the anterior third of the condyle and be placed anterior to posterior. They should be placed approximately 2 cm to 3 cm proximal to the prosthetic component. Once proper placement of the device in the condyle is achieved, a plate, which bypasses the comminuted portion of the fracture and allows for a minimum of four cortical screws to affix the plate to the proximal intact bone, should be selected. In osteoporotic bone, six cortices may be necessary for good plate fixation.
Submuscular plating is popular and can be used with the newer plates with percutaneous fixation of the proximal plate to the femoral shaft. Care must be taken for proper alignment and rotation of the femoral condyle and prosthetic component. If the patient has a long stem total hip component, the plates should overlap the stem component so there is no stress riser in the transition zone between the proximal aspect of the plate and distal end of the stem. If this area is not bridged, the resulting avenue of stress may result in fracture at this transition zone.
Intramedullary rodding allows the maximum use of indirect reduction and minimally invasive technique for fixation of these fractures. It works well in osteoporotic bone and allows for fixation of the distal fragment in most TKAs. It will not work in posterior stabilized knees and knees that have an extended patellar phlange. The supine position is used with the radiolucent triangle below the patient’s knee. Manual traction is placed at the knee and a small 3-4 cm incision is made in the medial parapatellar plane. The intercondylar notch is entered just below the patellar phlange and a guide wire is placed in line with the femoral axis. The guide wire should be placed under image intensification so that it is aligned in the longitudinal axis of the femur as well as just anterior to the posterior cortex in line with Blumenstat’s line before prosthetic replacement. The distal femur is then opened with flexible reamers and the supracondylar region and medullary canal are reamed. A rod long enough to bypass the comminuted area extending into the diaphysis of the femur at least 3 cm should be chosen. At least two, but preferably three, screws should fix the distal fragment and two screws should lock the nail proximally. Early range of motion is started and rapid healing is expected with this minimally invasive technique.
Revision TKA should be considered in supracondylar fractures when there is too little bone for a right angle device or an intramedullary rod of the distal fragment. It also should be used when a prosthetic component is loose. The fracture can be bridged with a stemmed medullary component and the area bone grafted with refixation of the femoral component. It is essential that stability be gained by appropriate sizing of the medullary stem into the diaphyseal segment of the femur. A line-to-line fit is used and a stem, which is the same size of the reamer that contacts the cortical wall, is selected.
Other fractures about the knee after TKA are rare. However, fractures of the tibia condyles and tibial shaft have been noted. If a tibial plateau is fractured and the prosthesis is loose, a stemmed tibial component with augmentation is used. If the shaft is fractured but the prosthesis is well fixed, the fracture is treated with casting or plating.
In summary, with supracondylar fractures about the knee when the components are well fixed, the surgeon must work around the prosthesis and fix the fracture. If the prosthesis is loose, the surgeon must revise the components and use stem components to secure the remaining bone stock to bridge the fracture during the healing process.