Introduction
Tibia fractures are the most common long bone fractures that result in nonunions and malunions. The tibia is subcutaneous, its blood supply is precarious, and complications of operative treatment are common. No other long bone engenders as much controversy as the tibia.
The anterior and medial surfaces of the tibia are subcutaneous, and the rest of the muscle attachments are loose. The tibia does not have a good periosteal blood supply, and the endosteal blood supply is not robust. Only one artery enters the diaphysis from the posterior junction of the proximal and middle third. Because the blood supply to the tibia is poor, nonunions can occur.
Tibia fractures can be splinted and stabilized in a cast. The results of casting, however, are associated with significant rates of nonunion. For this reason, several authors have attempted to use other methods of treating closed fractures of the tibial diaphysis.
Conservative Treatment
Conservative treatment requires skill; it is not simply placing a cast on a patient’s leg. The first attempts to standardize nonoperative treatment for the tibial shaft involved weight bearing, and the idea was that compression would assist fracture union. This proved to be an erroneous concept. Additionally, attempts were made to relieve pressure on the tibia by applying a patella tendon bearing (PTB) cast. This method also proved ineffective.
Clinical observations, however, demonstrated that these devices promoted healing of the tibial fracture. The observations were correct, but the reasons were not clarified until later. The blood flow through any bone is centrifugal. Blood flows horizontally through stiff canals. The pumping of blood through the cortex is mediated by pressure. For example, anything lying on the outer cortex of a bone will keep blood from flowing from the inside. Similarly, pumping actions on the outer surface of the cortex of a bone will push blood in and out of the cortex. The point of these weight bearing and PTB devices was that they would promote natural muscle forces to pump blood in and out of the cortex.
As these concepts developed, the standard shifted from a PTB device to a total contact type of casting or bracing. A total contact brace maintains a hydraulic pressure head by holding the muscles against the bone. This concentrates the pumping action of the muscles, and the hydraulic pressures further stabilize the bone.
The biomechanical and biolgical milieu in the early phases of healing tend to determine the nature of ultimate union. If a weight-bearing device is maximally effective, it should be applied within the first 6 weeks. The optimal treatment is to cast or splint the patient and at 2 to 4 weeks, apply a weight-bearing device. When molded well to the shape of the leg, reductions can be reliably maintained. With the hydraulic pressure supporting the bone, further shortening of 3 mm to 5 mm is the greatest amount of shortening that will occur.
Types of Fractures
Transverse fractures
Transverse fractures tend to be relatively unstable. Transverse fractures involve balancing one bone on another. Intuitive concepts of stability relate to shortening. A transverse fracture will not shorten, but it will wobble into an angular deformity.
Oblique fractures
Although an oblique fracture is unstable, it is rotational. When the deformity is reduced, the interosseous membrane becomes tight and is further supported by the hydraulic effects of a functional brace. The oblique fracture is stabilized by the brace and patients are able to ambulate. Often, an oblique fracture holds its reduction better than a transverse fracture.
Reduction
Standards for acceptability of reduction are subjective. Most clinicians allow at least 5° of varus and valgus and at least 7° to 10° of recurvatum and antecurvatum. Rotation should be within 10° of normal. Acceptable shortening is subjective. Generally, 1 cm of shortening is acceptable.
Bone Apposition
To achieve adequate bone apposition for union, at least 50% of the fragments must be in contact. If an excessive offset is allowed to proceed to union, then a large bump will form on the anterior tibia, which is both a cosmetic and functional problem. This mass of callus and bone becomes sensitive to local trauma. If the fracture does not unite, a translated tibia is difficult to repair. My "rule of thumb" is that apposition is satisfactory if a guide pin for an intramedullary nail can be driven across the fracture site without further reduction. This mandates that at least a partial canal is still present for later reconstruction and that adequate bony apposition exists. If a fracture can be held reduced in a functional brace, union can be reliably attained at approximately 12 weeks.
Bibliography
Dehne E. Treatment of fractures of the tibial shaft. Clin Orthop. 1969; 66:159-173.
Nicoll EA. Fractures of the tibial shaft. A survey of 705 cases. J Bone Joint Surg Br. 1964; 46:373-387.
Riemer BL, DiChristina DG, Cooper A, Sagiv S, Butterfield SL, Burke CJ 3rd, et al. Nonreamed nailing of tibial diaphyseal fractures in blunt polytrauma patients. J Orthop Trauma. 1995; 9:66-75.
Tischenko GJ, Goodman SB. Compartment syndrome after intramedullary nailing of the tibia. J Bone Joint Surg Am. 1990; 72:41-44.