Hyperguides

Orthopaedics / Orthobiologics

Bone Marrow Aspirates for Spinal Fusion

Travis Maak, BS Jonathan N. Grauer, MD
Article

Autologous bone is the gold standard grafting material for spinal fusion.1 Despite its success, however, autologous bone is associated with defined morbidities. Alternatives/adjuncts, such as bone marrow aspirates, have been advocated to reduce the limitations of autologous bone graft material.2,3 The background, preclinical data, clinical data, and potential options for bone marrow aspirates will be discussed in this tutorial.

Background

Blood production in the marrow requires a hematopoietic inductive microenvironment to support the manufacture of the 400 billion red cells and 10 billion white cells required daily. The osseous trabeculae and other stromal cells in the marrow support these functions.4,5Of specific note to the topic of bone marrow aspirates are the undifferentiated mesenchymal stem cells, which have the ability to proceed down any cell lineage and osteoprogenitor cells, which are prepared to proceed down bone-forming lineages. The interdependence of the marrow cells has begun to be evaluated revealing complex interactions such as the ability of osteoblasts to release monocyte- and granulocyte-stimulating factors, aiding blood cell production as well monocytes releasing factors that stimulate osteogenesis and maintain cortical and trabecular structures.6-8

In traditional bone grafting, structural or morcelized graft is harvested (most frequently from the iliac crest). Morcelized graft has osteogenic, osteoinductive, and osteoconductive components. The option has been raised of using aspiration as a means of capturing the osteogenic (and possibly osteoinductive) components of the marrow without the morbidities of greater graft harvest.

The ability of marrow cells to form bone has been recognized for more than a century (as identified by Goujon in 1869). Many cells obtained in this manner are recently formed hematopoietic cells. However, data from Muschler's group have shown that one out of 20,000 to 30,000 nucleated cells from marrow aspirates are progenitor cells - the cells desirable to facilitate bone formation.9 Further, the number of precursor cells obtained from an aspirate is related to the volume taken. Harvesting aspirates in no greater than 2 mL aliquots leads to the most efficient yield. Beyond this, one begins to draw an increasing proportion of venous backflow blood. Therefore, many surgeons who clinically use marrow aspirates will take multiple 2 mL aliquots of crest aspirate as opposed to greater volumes from a single site.

In addition, studies have shown that the number of precursor cells vary with patient age and gender.9,10 These data were obtained from a 57-patient cohort recruited for bone marrow assay immediately prior to elective orthopedic procedures. The marrow was harvested using a standardized technique of aspirating 2 mL samples from the anterolateral iliac crest. Aspirates obtained from female patients demonstrated a significant age-related decline in the number of cell colonies expressing alkaline phosphatase (an early marker for osteoblastic differentiation),11-13 while no decline was found in men. These differences may be associated with the pathophysiology of age-related bone loss and post-menopausal osteoporosis.10

Based on such background data, bone marrow-derived material has been evaluated in a number of preclinical animal studies3,14,15 and clinical studies.14,16-19 In such studies, marrow aspirates are combined with one of many different osteoconductive carriers to provide a framework for cell delivery. Synthetic materials, collagen, allograft, and demineralized bone matrix are some of the materials used for this purpose.

Preclinical Data

Multiple preclinical animal studies have been performed using long bone fracture and nonunion models to investigate the potential role of bone marrow aspirates.8,20-22 These data provide a foundation upon which animal spinal fusion studies are conducted to evaluate the potential role of bone marrow aspirates.15,23-26

The New Zealand white rabbit posterolateral fusion model is commonly used to study potential bone graft formulations for the spine. Lukas and colleagues studied a bone paucity model (one iliac crest) implanted with either blood or bone marrow aspirate.27 Fusion rates of 25% and 61%, respectively, were observed suggesting that bone marrow aspirate may be more effective than blood as a bone graft extender.

Tay and colleagues28 evaluated the efficacy of bone marrow aspirate with a type I collagen sponge with hydroxyapatite coating (Healos Bone Graft Replacement, DePuy Spine, Raynham, Mass) in the New Zealand white rabbit posterolateral spinal fusion model. Autologous iliac crest bone graft lead to fusion in 75% of the rabbits, Healos alone in 20% of the rabbits, and bone marrow aspirate from the long bones with Healos in 100% of the rabbits. In contrast to these findings, Boden and researchers found no fusions with Healos and iliac crest bone marrow in the same model.29 Although Tay and Boden report conflicting results, the results may be related to the site of marrow harvest.

Boden and colleagues23 also evaluated hydroxyapatite with autograft or bone marrow aspirate in the New Zealand white rabbit model. Fusion rates of 50% and 0% were observed, respectively. Possibly, this was related to the carrier not being appropriate and, thus, highlights the need for ensuring that all components of a bone graft composite are optimized.

Kai and colleagues24 used a rabbit fusion model to compare porous ceramics combined with iliac graft, marrow aspirate, or aspirate with recombinant human bone morphogenetic protein (rhBMP)-2. Data from this study demonstrated 100% fusion rates with both marrow aspirate and aspirate with rhBMP-2. These rates supercede the 50% fusion rate seen with ceramics or 66% seen with iliac crest graft. The findings suggest that bone marrow aspirate may be an effective substitute for iliac crest. In addition, the similar fusion rates seen with aspirate and aspirate combined with rhBMP-2 suggest that the less expensive alternative, aspirate alone, may be an effective treatment alternative.

Overall, these studies suggest that bone marrow aspiration may be an effective alternative to the current gold standard autograft if combined with the correct carrier. To substantiate this potential, however, requires human clinical study.

Clinical Data

The clinical application of marrow aspirates was introduced in the non-axial skeleton. Tibial nonunion healing was accelerated via percutaneous injection of bone marrow aspirates in the 1980s.30 This study found effective fracture healing with radiographic union 6 months post-injection. Since this, data obtained from reports of more than 100 fractures treated with stabilization and autologous marrow transplantation demonstrated an 80% success.2 With positive results in the preclinical arena and long bone clinical trials, clinical evaluations of bone marrow aspirates for clinical spine pathology have been initiated.

A side-by-side comparison of Healos/bone marrow aspirate and autograft was presented by Kitchel and researchers at the 2004 International Meeting on Advanced Spine Techniques.31 With 25 patients undergoing instrumented fusion, a fusion rate of 80% was found on the Healos/bone marrow aspirate side and 84% on the autograft side. Although side-by-side comparisons have potential limitations, such as stabilizing for the opposite side and potential cross osteoinductivity, data suggested that bone marrow aspirate with the correct carrier might lead to comparable fusion rates as autograft in this setting.

Wetch and researchers32 similarly evaluated Healos/bone marrow aspirate or autograft in an anterior lumbar interbody fusion model. At 1 year, fusion rates for one- or two-level procedures were 96% and 91%, respectively.

Price and colleagues33 used a posterior instrumented adolescent scoliosis fusion model. Three different bone grafting materials were evaluated: autograft, freeze-dried corticocancellous allograft, and a composite graft of bone marrow aspirate and demineralized bone matrix (DBM). Failure rates, defined as pseudoarthrosis or loss of correction, were 12.5% with iliac crest bone graft, 28% with allograft, and 11.1% with marrow and DBM. As no significant morbidity was associated with the marrow aspirate and fusion rates equivalent to that seen with traditional iliac crest bone graft, marrow aspirate and DBM seemed to offer an encouraging potential option for patients with adolescent scoliosis.

Bone marrow aspiration has also been studied in anterior cervical fusion.34In this prospective, nonrandomized trial with a minimum 2-year follow-up, the aspirate was combined with hydroxyapatite and implanted in a titanium alloy cage. A 24% increase in the hydroxyapatite mass in the implant core was seen 2 years after surgery. At this point, 92% of the patients experienced relief of their symptoms and none required re-operation. Despite the lack of a control group, these data effectively demonstrated an equivalent clinical efficacy of the implant relative to current literature data, while again eliminating the morbidity associated with autograft harvest.

Overall, these clinical studies provide encouraging data for the use of bone marrow aspirates. When combined with osteoconductive carriers, results comparable to autograft are being reported for select applications. Of note, the models in which these clinical studies have been conducted are not the most challenging fusion environments (adolescent spines and anterior column reconstructions). Clearly further study in these and more challenging fusion environments are warranted.

Additional Options

Because progenitor cells are thought to be the primary active agent in bone marrow aspirates, it seems logical that concentrating such cells would increase the efficacy of bone marrow aspirate products. Methods such as centrifugation, culture amplification, and selective retention have been introduced.

Connolly and colleagues evaluated different means of cell concentration for aspirates from the New Zealand white rabbit iliac crest.35 Concentration techniques evaluated included: vortex (whole marrow mixing), simple centrifugation, isopyknic centrifugation (centrifugation through a density column), gravity sedimentation (sedimentation through a density column), and diffusion chamber (osmotic diffusion through a semi-permeable membrane). The resultant concentrated suspensions were analyzed for cell count and alkaline phosphatase activity. Cell concentration was increased without significant loss of cell viability. The concentrated cells were injected in a rabbit radius nonunion model and produced proportionate increases in osteogenesis and calcium deposition.

A relatively new method designed to concentrate progenitor cells from bone marrow aspirates known as Cellect was developed by Muschler in 1998.36 Cellect utilizes an affinity column to increase concentrations of osteoprogenitor cells by three- to four-fold. Post-processing graft clotting and preparation is then performed to optimize handling.

In addition to osteoprogenitor concentration techniques, studies have also investigated the potential of osteoprogenitor cloning. This method uses ex vivo cell culture to amplify pluripotent osteoprogenitor cells from the 1 per 100,000 nucleated cells concentration seen in vivo.25,37 The culture-expanded cloned osteoprogenitor cells can be re-implanted to aid fusion. The difficulty with this technique is that cells have a tendency to terminally differentiate as they are clonally expanded, resulting in a decreased concentration of cells capable of osteogenesis. Moreover, establishing cells as belonging to an osteoprogenitor lineage can be challenging.

Cloned osteoprogenitor cells produce mature osseous tissue earlier and to a greater degree than mixed marrow cell aspirates.25 An osteoprogenitor cell, D1-BAG, was compared to mixed bone marrow cell aspirate in a rat lumbar fusion model. Successful fusion was produced in 100% of the animals receiving D1-BAG, whereas 50% and 0% fusion rates were seen in animals receiving mixed marrow cells and carrier alone, respectively. Thus, cloned osteoprogenitor cells tended to produce mature osseous tissue more rapidly and in larger quantity during spinal fusion and associated fusion rates were significantly higher in this preclinical setting.

Conclusions

The surgical movement toward less invasive methods of treatment has led to rigorous study of bone graft adjuncts/alternatives for facilitating spinal fusion. Bone marrow aspirates are a promising graft material if combined with an appropriate carrier and used in specific, appropriate situations. Means of further concentrating and harnessing the osteogenic properties of marrow aspirates such as cell concentration and clonal expansion are promising technologies being evaluated.

References

  1. Phemister D. Treatment of ununited fractures by onlay bone grafts without screw or tie fixation and without breaking down of the fibrous union. J Bone Joint Surg Am. 1947; 29:946-960.
  2. Connolly JF. Injectable bone marrow preparations to stimulate osteogenic repair. Clin Orthop. 1995; 313:8-18.
  3. Connolly JF, Guse R, Tiedeman J, et al. Autologous marrow injection for delayed unions of the tibia: A preliminary report. J Orthop Trauma. 1989; 3:276-282.
  4. Owen M. Marrow stromal stem cells. J Cell Sci Suppl. 1988; 10:63-76.
  5. Owen M, Friedenstein AJ. Stromal stem cells: Marrow-derived osteogenic precursors. Ciba Found Symp. 1988; 136:42-60.
  6. Triffitt JT. Initiation and enhancement of bone formation. A review. [erratum appears in Acta Orthop Scand 1988; 59:625]. Acta Orthop Scand. 1987; 58:673-684.
  7. Broudy VC, Zuckerman KS, Jetmalani S, et al. Monocytes stimulate fibroblastoid bone marrow stromal cells to produce multilineage hematopoietic growth factors. Blood. 1986; 68:530-534.
  8. Strates BS, Stock AJ, Connolly JF. Skeletal repair in the aged: A preliminary study in rabbits. Am J Med Sci. 1988; 296:266-269.
  9. Muschler GF, Boehm C, Easley K. Aspiration to obtain osteoblast progenitor cells from human bone marrow: The influence of aspiration volume. J Bone Joint Surg Am. 1997; 79:1699-1709.
  10. Muschler GF, Nitto H, Boehm CA, et al. Age- and gender-related changes in the cellularity of human bone marrow and the prevalence of osteoblastic progenitors. J Orthop Res. 2001; 19:117-125.
  11. Bianco P, Riminucci M, Bonucci E, et al. Bone sialoprotein (BSP) secretion and osteoblast differentiation: Relationship to bromodeoxyuridine incorporation, alkaline phosphatase, and matrix deposition. J Histochem Cytochem. 1993; 41:183-191.
  12. Lee K, Deeds JD, Bond AT, et al. In situ localization of PTH/PTHrP receptor mRNA in the bone of fetal and young rats. Bone. 1993; 14:341-345.
  13. Turksen K, Aubin JE. Positive and negative immunoselection for enrichment of two classes of osteoprogenitor cells. J Cell Biol. 1991; 114:373-384.
  14. Garg NK, Gaur S, Sharma S. Percutaneous autogenous bone marrow grafting in 20 cases of ununited fracture. Acta Orthop Scand. 1993; 64:671-672.
  15. Tiedeman JJ, Connolly JF, Strates BS, et al. Treatment of nonunion by percutaneous injection of bone marrow and demineralized bone matrix. An experimental study in dogs. Clin Orthop. 1991; 268:294-302.
  16. Nade S, Armstrong L, McCartney E, et al. Osteogenesis after bone and bone marrow transplantation. The ability of ceramic materials to sustain osteogenesis from transplanted bone marrow cells: Preliminary studies. Clin Orthop. 1983; 181:255-263.
  17. Bhan S, Mehara AK. Percutaneous bone grafting for nonunion and delayed union of fractures of the tibial shaft. Int Orthop. 1993; 17:310-312.
  18. Bruder SP, Jaiswal N, Haynesworth SE. Growth kinetics, self-renewal, and the osteogenic potential of purified human mesenchymal stem cells during extensive subcultivation and following cryopreservation. J Cell Biochem. 1997; 64:278-294.
  19. Nade S. Bone-graft surgery reappraised: The contribution of the cell to ultimate success. Br J Surg. 1970; 57:752-756.
  20. Connolly JF. Common avoidable problems in nonunions. Clin Orthop. 1985; 194:226-235.
  21. Lippiello L, Chavda D, Connolly J. Colony-forming efficiency response of bone marrow stromal cells to acute blood loss. J Orthop Res. 1992; 10:145-148.
  22. Stegemann P, Lorio M, Soriano R, et al. Management protocol for unreamed interlocking tibial nails for open tibial fractures. J Orthop Trauma. 1995; 9:117-120.
  23. Boden SD, Martin GJ Jr, Morone M, et al. The use of coralline hydroxyapatite with bone marrow, autogenous bone graft, or osteoinductive bone protein extract for posterolateral lumbar spine fusion. Spine. 1999; 24:320-327.
  24. Kai T, Shao-qing G, Geng-ting D. In vivo evaluation of bone marrow stromal-derived osteoblasts-porous calcium phosphate ceramic composites as bone graft substitute for lumbar intervertebral spinal fusion. Spine. 2003; 28:1653-1658.
  25. Cui Q, Ming Xiao Z, Balian G, et al. Comparison of lumbar spine fusion using mixed and cloned marrow cells. Spine. 2001; 26:2305-2310.
  26. Muschler GF, Nitto H, Matsukura Y, et al. Spine fusion using cell matrix composites enriched in bone marrow-derived cells. Clin Orthop. 2003; 407:102-118.
  27. Curylo LJ, Johnstone B, Petersilge CA, et al. Augmentation of spinal arthrodesis with autologous bone marrow in a rabbit posterolateral spine fusion model. Spine. 1999; 24:434-438; discussion 8-9.
  28. Tay BK, Le AX, Heilman M, et al. Use of a collagen-hydroxyapatite matrix in spinal fusion. A rabbit model. Spine. 1998; 23:2276-2281.
  29. Boden SD, Kraiwattanapong C, Louis-Ugbo J, et al. Comparison of Healos/bone marrow to Infuse (rhBMP-2/ACS) with a collagen-ceramic sponge bulking agent as graft substitutes for lumbar spine fusion. Paper presented at: North American Spine Society; 2004; Chicago, Illinois.
  30. Connolly JF, Shindell R. Percutaneous marrow injection for an ununited tibia. Nebr Med J. 1986; 71:105-107.
  31. Kitchel S. Prospective randomized evaluation of Healos/bone marrow aspirate versus autologous iliac crest bone graft in posterolateral lumber spine fusion. Paper presented at: IMAST; 2004; Bermuda.
  32. Welch W, Gerszten P, Sherman J, et al. A prospective randomized study of interbody fusion: Bone substitute or autograft. Paper presented at: BioTechnologies for Spinal Surgery; 2002; Halle, Germany.
  33. Price CT, Connolly JF, Carantzas AC, et al. Comparison of bone grafts for posterior spinal fusion in adolescent idiopathic scoliosis. Spine. 2003; 28:793-798.
  34. Papavero L, Zwonitzer R, Burkard I, et al. A composite bone graft substitute for anterior cervical fusion: Assessment of osseointegration by quantitative computed tomography. Spine. 2002; 27:1037-1043.
  35. Connolly J, Guse R, Lippiello L, et al. Development of an osteogenic bone-marrow preparation. J Bone Joint Surg Am. 1989; 71:684-691.
  36. Muschler GF. Method of preparing a composite bone graft. U.S. Patent #5,824,084 issued: Oct. 20, 1998.
  37. Bruder SP, Jaiswal N, Ricalton NS, et al. Mesenchymal stem cells in osteobiology and applied bone regeneration. Clin Orthop. 1998; 355 (Suppl):S247-S256.