Hyperguides

Orthopaedics / Trauma

Fixation of Low-Energy Tibia Fractures

Christopher M. Larson, MD
Article

Bracing

Most fractures of the tibial diaphysis can be managed with functional bracing. Many fractures, however, require operative stabilization. Grade III open fractures are unstable and require fixation. Closed fractures and grade I and grade II open fractures often have sufficient soft tissue stability, so functional brace treatment should be an option.

Internal Fixation

Not all fractures are amenable to nonoperative treatment. Some patients are not tolerant of a deformity and wish to proceed with internal fixation. Some fractures cannot be held adequately. Many fractures occur in polytrauma patients or are associated with an ipsilateral femoral shaft fracture. These are relative indications for internal fixation. I strongly believe that an ipsilateral femoral shaft fracture is a clear indication for surgery. A polytrauma setting, however, should be considered only a relative indication for internal fixation. In my experience, approximately 20% of blunt polytrauma patients who sustain a fracture of the tibial shaft do well with nonoperative treatment. This mandates that the fracture is low energy and that the vascular status of the limb can be monitored.

The mechanism of injury is also important. An indirect force, generally rotational, usually causes low-energy tibia fractures. These fractures tend to unite readily and have a low rate of complication. Fractures from direct blows tend to heal more slowly and tend to be associated with a higher rate of vascular injury, particularly compartment syndrome.

One of the most important prognostic signs in evaluating a closed fracture of the tibia is the amount of initial displacement. If the tibia is completely offset and 100% displaced, even the limited soft tissues of the bone have been torn sufficiently that the bones can displace. This is an indication of a severe disruption of the biology of the bone. The most common site of nonunion is the distal third, but this is also the site of fractures with the highest rate of soft tissue injury. Similarly, when the degree of soft tissue injury is controlled, the most likely site for nonunion is the junction of the proximal and middle thirds, which is the site of the entry of the nutrient artery.

The tibia is also sensitive to locking mode. Again, this is unlike the femur, where locking of the fracture does not retard healing. Locking tibial nails seems to significantly affect fracture union. The reasons for this are not clear, but it is important not to extrapolate results of femoral fractures to the tibia.

This is not to imply that no fracture should have static nailing. When unlocked nails are used routinely in the tibia, a significant rate of malunions, particularly as a result of external rotation, is seen. Malunion rates of 20% are common. However, locking screws should be used judicially. If a fracture requires internal fixation but can be supported in a cast or brace, then locking screws should be avoided. If the patient cannot tolerate a cast for systemic or personal reasons, a locked nail should be used.

A theoretical concern in nailing a tibial diaphysis is the creation of a compartment syndrome. Early on, this was a serious concern. It was found, however, that some cases of compartment syndrome were related to the use of fracture tables. When a reamer or nails are inserted into the bone, pressures in the muscle compartments rise but will return to normal in a short while. This phenomenon, however, is exacerbated by even slight overdistraction of the fracture. For this reason, fracture tables should be used judiciously.

Plating

Limited information has been published about plating a tibial diaphysis. It is almost understood that this has been associated with a high rate of complications of both union and infection. This is despite the only reported large series showing a very low rate of complications. Other surgeons’ experience has simply not borne out these studies. In addition, once a fracture is plated, a patient cannot be full weight bearing until the fracture is united for fear of implant failure. Tibia fractures are slow to heal, and this may prove an excessive period of nonweight bearing.

Tibial plates often require metal removal, as well. Because the bone is slow to remodel, notching will often occur, leaving the bone thin and atrophic and at risk for refracture.

New techniques of plating are being developed including locked plating and percutaneous plating. In addition, implants have a lower profile and are becoming more fatigue resistant because of improvements in metallurgy. The flexibility of these implants may allow more callus formation. The plating implants are being designed more biologically and, as a result, cause less damage to the periosteal blood supply. Percutaneous applications are also less damaging to the blood supply. With the advent of these techniques, plating the tibial diaphysis should be revisited.

External Fixation

External fixation is generally considered a technique for severe open fractures. There are many large series, however, that involve external fixation to treat closed and minor open fractures of the tibia. In these cases, good statistical results have been reported. A concern of external fixation is later reconstructions. Pin sites all have the potential to become a source for infection. If the fracture does not unite with the external fixator alone and a reconstruction is necessary, there is a significant risk for infectious complications. Two treatments have been recommended for this condition, plating and nonreamed nailing. Reamed nailing is not acceptable because it has been associated with high rates of infection.

Plating for nonunion has the same issues as plating for acute fractures. Excellent statistical results have been seen, but the time to union sometimes is prolonged. These are patients who have waited approximately 1 year for a reconstructive procedure and then cannot bear weight for the entire time the fracture is uniting.

Nonreamed nails have been shown to be equally efficacious in reconstructing the tibia after an external fixator. These nails are easier to insert and allow immediate weight bearing. Why they work is not clear. It is possible that, while broaching the nonunion, small pieces of bone are pushed to the periphery of the nail and serve as bone graft with soft tissue attachments.

Conclusion

When fixation of low-energy tibia fractures is required, intramedullary nails are the preferred method of treatment. Static locking should only be used if necessary. Plates and external fixation should be reserved for unusual circumstances.

Bibliography

Bone LB, Sucato D, Stegemann PM, Rohrbacher BJ. Displaced isolated fractures of the tibial shaft treated with either a cast or intramedullary nailing. An outcome analysis of matched pairs of patients. J Bone Joint Surg Am. 1998; 80:1084-1085.

Keating JF, O'Brien PI, Blachut PA, Meek RN, Broekhuyse HM. Reamed interlocking intramedullary nailing of open fractures of the tibia. Clin Orthop. 1997; 338:182-191.

Levy AS, Bromberg J, Jasper D. Tibia fractures produced from the impact of a baseball bat. J Orthop Trauma. 1994; 8:154-158.

McQueen MM, Christie J, Court-Brown CM. Acute compartment syndrome in tibial diaphyseal fractures. J Bone Joint Surg Br. 1996; 78:95-98.

Nicoll EA. Fractures of the tibial shaft. A survey of 705 cases. J Bone Joint Surg Br. 1964; 46:373-387.

Riemer BL, DiChristina DG, Cooper A, Sagiv S, Butterfield SL, Burke CJ 3rd, Lucke JF, Schlosser JD. Nonreamed nailing of tibial diaphyseal fractures in blunt polytrauma patients. J Orthop Trauma. 1995; 9:66-75.

Ruedi T, Webb JK, Allgower M. Experience with the dynamic compression plate (DCP) in 418 recent fractures of the tibial shaft. Injury. 1976; 7:252-257.