J. David Blaha, MD Reprinted with permission from Blaha JD. A medial pivot geometry. Orthopedics. 2002; 25:963-964.
Article

Since the work of Zuppinger1 and the treatise published by Strasser,2 orthopedists and engineers who designed total knee prostheses believed human knee motion was guided by the cruciate ligaments acting in a crossed four-bar link. This model requires the ligaments be taut so they can guide range of motion. A consequence of the kinematics of a crossed four-bar link is the phenomenon of rollback, i.e., the progressive movement of the femoral condyle posteriorly relative to the tibia with increasing flexion.3

Total knee designs that preserve the posterior cruciate ligament (PCL) have had little conformity between the femoral and tibial components to allow for rollback. Those designs that remove the cruciate generally provided a cam and post mechanism that, when it engaged, forced rollback of the femoral component relative to the tibial component.

Modern kinematic studies of the human knee confirm a model of human knee motion published in the mid-19th century.4-6 Instead of progressive rollback, the knee remains nearly stable on the medial side like a ball in a socket, whereas the femoral component contacts the tibial component on the lateral side either posteriorly or anteriorly to accommodate axial rotation of the tibia. The cruciate ligaments are not equally tight throughout motion and therefore cannot act as a crossed four-bar link. Rather, more stress occurs in the anterior cruciate ligament (ACL) in extension and the PCL in flexion. The innervation of the cruciate ligaments suggests they function as stretch receptors and thus position sensors as well as "check reins" to motion.7

Gait analysis of patients with ACL or PCL deficiency demonstrates abnormality compared to normal walking.8 In the "cruciate deficient" gait during level walking, less knee joint flexion occurs during stance phase when comparing cruciate deficient knees to normal knees. This "quadriceps avoidance" gait can be attributed to the patient establishing a degree of flexion at which the knee can be stabilized (e.g., by cocontraction of the quadriceps and hamstring muscles) and retaining the knee in that position during the stance phase of gait. Cruciate ligament deficiency also can lead to abnormalities during stair climbing, rising from a chair, and walking on uneven ground.

Patients with total knee joint replacements have been noted to have an abnormal gait similar to the gait of patients who have cruciate deficiency and also have demonstrated abnormalities in stair climbing and getting in and out of a chair.

Video fluoroscopic studies have not demonstrated the expected femoral rollback (i.e., by the crossed four-bar link model) as the total knee is actively used but rather a "paradoxical" sliding forward of the femur on the tibia similar to the sliding forward seen in an ACL-deficient knee.9 This paradoxical motion has been demonstrated to the greatest degree in cruciate ligament preserving knees but also has been seen in cruciate ligament sacrificing/substituting knees as the femoral component slides forward until the cam and post mechanism engages.

A total knee prosthesis designed to emulate a normally stable knee should achieve stability in the anterior and posterior directions. Based on the kinematic studies that have shown the medial side of the joint to be virtually stable, such stability on the medial side can be achieved if the knee prosthesis is designed as a "ball-in-socket" articulation. For axial rotation of the tibia, the lateral side is designed to allow anterior or posterior contact of the femoral component on the tibial component.

The medial and lateral condyles of the medial pivot total knee prosthesis are spherical (Slide 1, Slide 2 and Slide 3). The tibial component has an exactly conforming socket on the medial side and an arcuate trough on the lateral side that allows anterior or posterior contact of the femoral component to permit axial rotation of the tibia. This prosthesis has been used since January 1998.

In the author’s series, 61 knees (61 patients) had 2-year follow-up. The 27 men and 34 women had an average age of 64 years, an average Knee Society knee score of 91, and average 115° range of motion. Of these, 56 patients had no unusual limitation to function in other joints, and average Knee Society function score was 89.

This total knee design is considered a cruciate-sacrificing and substituting prosthesis, but it is possible in some cases to retain the cruciate ligament. In a multicenter study of 401 patients, 60% of knees were cruciate-sacrificing with average 119° range of motion at 2-year follow-up, and 40% were cruciate-retaining with average 118° range of motion at 2-year follow-up.

A comparison study was performed of 43 patients who had a medial pivot design in one knee and a different total knee prosthesis in the other knee. A majority of patients rated the medial pivot knee superior in ease of rehabilitation and motion, stability, and overall satisfaction.

Replacement of the human knee with a prosthesis based on "medial pivot" kinematics provides stability in the anterior and posterior directions. The "kinematic conflict," based on the concept that the knee moves as a crossed four-bar link, has not been a problem clinically as the knees have had an excellent average range of motion. The ongoing comparison study suggests patients can perceive a difference in function that leads to a preference for medial pivot articulation.

References

  1. Zuppinger H. Die active flexion. In: Unbelasteten Kniegelenk: Züricher Habil Schr. Wiesbaden, Germany: Bergmann; 1904:703-763.


  2. Strasser H. Lehrbuch der Muskel—und Gelenkmechanik. III Band Die untre Extemitast. Berlin, Germany: Springer; 1917.


  3. O’Connor J, Shercliff T, Fitzpatrick D, et al. Geometry of the knee. In: Akeson WH, O’Connor JJ, Daniel DM, eds. Knee Ligaments: Structure, Function, Injury and Repair. New York, NY: Raven Press; 1990.


  4. Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop. 1993; 290:259-268.


  5. Iwaki H, Pinskerova V, Freeman MA. Tibiofemoral movement 1: The shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br. 2001; 82:1189-1195.


  6. Mancinelli CA, Simons WH, Kish VL, Thyagarajan G. Kinematics of the human knee. An investigation using cadaver knees in an open-chain model with differential hamstring loads. Clin Orthop. In press.


  7. Barrack RL, Skinner HB. The sensory function of knee ligaments. In: Akeson WH, O’Connor JJ, Daniel DM, eds. Knee Ligaments: Structure, Function, Injury and Repair. New York, NY: Raven Press; 1990.


  8. Simon SR. Gait—normal and abnormal. In: Insall JN, Scott WN, eds. Surgery of the Knee. Philadelphia, Pa: Churchill Livingstone; 2001.


  9. Dennis DA, Komistek RD, Colwell CE Jr, et al. In vivo anteroposterior femorotibial translation of total knee arthroplasty: A multicenter analysis. Clin Orthop. 1998; 356:47-57.