Knee joint replacement is one of the most successful operations in orthopedic surgery. Over 95% of patients have excellent relief of pain, good mobility, and the ability to return to most of their normal activities of daily living.1-4 Despite this, there are some common misconceptions about the surgery that can cause consternation among surgeons and their patients.

Surgical exposure is facilitated if the operation is performed with the knee flexed, rather than extended. Few retractors are necessary and the soft tissues fall to the side. The medial side of the tibia should be exposed back to the level of the midcoronal plane. This is performed by externally rotating the flexed knee and peeling off the medial tissues sub-periosteally (Slide 1).

The lateral side of the tibia should be exposed by removing a portion of the fat pad and lateral meniscus. A retractor can then be placed over the lateral border of the tibia in the midcoronal line. At this point, the patellofemoral ligament should be cut. This is not only beneficial for patellar tracking but permits further lateral retraction, allowing removal of the lateral meniscus. If the knee is then hyperflexed and pressure exerted down on the femur, the tibia will sublux forward allowing its full exposure without the necessity of a posterior retractor.

It has been alleged (improperly) that a lateral release is necessary to obtain good patellar tracking. This is not true. The femoral component should be slightly externally rotated from the mid trochlear or transepicondylar lines and the tibial component aligned with the medial third of the patellar tendon insertion. If you combine this with removing patellar bone and cartilage equal in thickness to the implant being used and positioning the implant slightly medial on the patella, the patella will track well. Using these techniques, a 2.5% 5-year lateral release rate using one prosthesis, the Genesis II (Smith & Nephew, Memphis, Tenn), has been reported.5

There is a misconception that surgical cutting guides are foolproof. If the saw blade is not placed directly on the block, the bone resection will be improper. Slotted blocks alleviate some, but not all, of this problem. The problem is rectified by thinking about the saw and where it is going. However, improper saw technique is often taught to residents, and this results in improper resections. A cutting blade placed improperly on the posterior aspect of the femoral cutting block will result in sufficient bone being removed. When the trial femoral component is inserted it will go improperly in flexion.

Equally as important as cutting on the block is fixing the block to the bone. It is a misconception that only two pins are needed to fix a block. In osteopenic bone, three or more pins may be necessary. Likewise the first pin should not be inserted into the hardest part of the bone (the concave side of a deformity). It may deflect on the hard bone, moving the block to an improper position.

There is a misconception that bone cutting is the most important part of any knee replacement. Most product brochures from the manufacturers of knee implants concentrate almost exclusively on bone cuts. Bone cuts that are 2° to 3° or 2 to 3 mm different from the "optimum" usually are of no clinical significance. Soft-tissue balancing and flexion-extension space balancing are important.

Another misconception is that if the knee does not fully extend at the time of surgery, it will gradually extend as time passes postoperatively. With the tourniquet inflated (i.e., without a hemarthrosis in the knee) the knee should extend fully with the trial implants in place. This can be determined by performing the Bounce Test. The leg is lifted by the ankle in the extended position after which the surgeon presses proximally on the sole of the foot. If there is any flexion contracture at this point, the knee will suddenly flex. It is at this time that the flexion contracture must be addressed. This may involve removing any remaining posterior osteophytes, rechecking the rectangularity of the flexion and extension spaces, and, if necessary, removing slightly more bone from the distal femur.

On reviewing the nonseptic cases that were referred for revision, most were due to soft-tissue problems, not bony abnormalities. Four percent had identifiable implant malposition problems. Thirty-four percent had a flexion-extension space mismatch, and 21% had an insufficient correction of an initial fixed deformity (Slide 2). Many patients brought their operative reports which detailed various jigs, blocks, and bone cuts but made no mention at all of soft-tissue balance. The surgeon must ascertain that the extension space is rectangular and that it is equal in size to the flexion space. Only when those two steps are performed can the surgery be deemed to have been done properly.

Finally, there is a misconception that a knee replacement is a harder operation to perform than a hip replacement. On reviewing the last 100 primary hip replacements and primary knee replacements performed at the Hospital for Special Surgery, there was no statistical difference in the operative times between hips and knees. For revisions, knee replacements took less time than hip revisions.

The most important part of performing a knee replacement (as well as any surgical procedure) is preoperative planning. Know what you will do not only if everything goes according to plan but in case the unexpected occurs. With proper planning, good exposure, proper use of instrumentation, and proper soft-tissue balancing, the results of total knee replacement will continue to be excellent.

References

  1. Laskin RS. The Genesis total knee replacement: 10-year followup study. Clin Orthop. 2001; 388:95-102.


  2. Buechel FF Sr, Buechel FF Jr, Pappas MJ, D’Alessio J. Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop. 2001; 388:41-50.


  3. Rodriguez JA, Bhende H, Ranawat CS. Total condylar knee replacement: A 20-year followup study. Clin Orthop. 2001; 388:10-17.


  4. Ritter MA, Berend ME, Meding JB, Keating EM, Faris PM, Crites BM. Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement. Clin Orthop. 2001; 388:51-57.


  5. Laskin RS. Lateral release rates after total knee replacement. Clin Orthop. 2001; 392:88-93.