Hyperguides

Orthopaedics / Hand & wrist

Modern Flexor Tendon Repair

Scott Crow, BS Nathan Taylor, MD Ryan Beekman, MD Melvin Rosenwasser, MD
Article

Although surgeons' understanding and techniques have improved significantly over the past 30 years, flexor tendon repair continues to be challenging and unpredictable outcomes often ensue. For many years, surgeons believed that lacerated flexor tendons in the finger should not undergo primary repair at all and were instead treated with flexor tendon grafting. Primary tendon repair in the flexor tendon sheath was once referred to as "no mans land" by Bunnell because of poor repair results in zone II.1 This concept changed in 1967 when Kleinert reported good and excellent outcomes after primary repair in zone II of the hand.2 Continuous research has contributed to our evolving techniques and superior outcomes. An overview of the current principles in primary flexor tendon repair will be presented in this tutorial.

General Principles

Flexor tendon repair was once considered a surgical emergency. Surgeons today believe that this procedure is not emergent, but urgent: patients do quite well if the severed tendon is repaired within the week after the injury. The goal of an ideal repair is restoration and function and, as noted by Strickland,3 the characteristics of an ideal primary flexor tendon repair include:

  • Sutures that are easily placed in the tendon,
  • Secure suture knots,
  • Smooth juncture of tendon ends,
  • Minimal gapping at the repair site,
  • Minimal interference with tendon vascularity, and
  • Sufficient strength throughout healing to permit the application of early motion stress to the tendon.

Many techniques have been described to satisfy these criteria for an ideal repair. Despite this variation, some general conclusions can be made.

Suture Technique

Prevention of gapping to less than 3 mm is important to minimize adhesions formation and reduce the work of flexion. Gapping can be minimized with suture techniques that provide for the requisite suture tendon interface grasp and materials that reduce material stretch.

Number of strands
A fundamental principle in tendon repair is that the strength of the repair is generally proportional to the number of suture strands that cross the repair site. Four-strand core sutures reliably test about twice as strong as two-strand methods, and six-strand repairs have been shown to be three times stronger than repairs that use two strands.3 Investigators have found that at least a four-strand repair is required to withstand light active motion without gapping.4 Because of this observation, two-strand techniques that have traditionally been popular are losing favor. There are now a number of four-, six-, and even eight-strand techniques that are available. Although these multi-strand repairs are stronger, they have the disadvantage of being technically difficult, especially when resecting the critical A2 and A4 pulleys. When repairing a tendon, tissue handling must be minimized to reduce the risk of fibrosis and adhesions. With a more difficult repair, there is the possibility of excessive manipulation. Increased bulk at the repair site is also a disadvantage of a large, multi-strand repair.

Core suture
A number of core suture techniques have been developed to increase the strength of the repair. Some of the popular suture methods include the Kessler, the modified Kessler, Tajima modification, Tsuge looped suture, Strickland, four-strand cruciate, Becker, and Savage. There are also non-suture core repairs, such as the Teno Fix system (Ortheon Medical, Winter Park, Fla). Studies have shown that the core suture is strongest when there are multiple sites of interaction between the tendon and the suture.5 Surgeons have also learned that a dorsal rather than a palmar placement of core suture results in a stronger repair6, but this may compromise the vincular vascular supply that originates dorsally.

Core Suture Techniques

Kessler7 The Kessler core suture is a two-strand repair technique that has been popular, although it is being replaced by stronger, multi-strand repairs (Slide 1).

Modified Kessler and Tajima modification of the Kessler
The modified Kessler and Tajima modification of the Kessler techniques attempt to minimize manipulation of the tendon. Suture knots are tied within the repair site, which adds more bulk (Slide 2).

Four-strand cruciate repair
This repair technique, first described by Mclarnney et al in 1999, has many characteristics of an ideal repair (Slide 3). This technique has proven faster than the other major four-strand repair techniques, eliminates knots from the junction site, and requires approximately twice the force to generate a 2-mm gap as the modified Kessler, Strickland, or modified Savage.8

Strickland
The Strickland core suture is a simplified four-strand repair in which a basic two-strand core suture is supplemented by a horizontal-mattress suture. A running lock stitch epitendinous suture is added to complete the repair (Slide 4).9

Modified Becker
The modified Becker technique is a four-strand repair with two knots outside of the repair site. The repair consists of criss-crossing a running suture using a double-armed needle (Slide 5).10

Savage/Modified Savage11,12
The Savage/modified Savage is another popular core suture technique that uses four or six strands in the repair (Slide 6).

Teno Fix
The Teno Fix repair technique is different from traditional suture repairs. The Teno Fix device is a single, multi-filament, 2-0 stainless steel suture that is joined on both ends by an intratendinous stainless steel anchor (Slide 7). The Teno Fix tendon repair system was developed to take advantage of the properties of stainless steel, while avoiding the difficulties of handling a suture of this material. The Teno Fix is placed in the tendon through anchors that are secured by twisting and capturing fibers in the corkscrew-like coil (Slide 8). Results from a biomechanical study have shown that energy absorbed up to a 2-mm gap was significantly greater for the Teno Fix system than for 3-0 or 4-0 cruciate repairs.13 A circumferential suture is usually added to the Teno Fix for additional strength. The Teno Fix device has an added advantage over traditional repair techniques in that the actual repair can be less technically demanding once the surgeon is trained in the technique. The Teno Fix, along with some standard suture repairs, also allows early active motion immediately after repair due to its greater strength.

Circumferential suture
Researchers have found that the addition of a circumferential suture to a core suture significantly increases the strength of the repair.14 The function of the epitendinous suture is not only to provide strength but also to smooth out the surface of the repair and allow for more efficient gliding of the tendon postoperatively. There are numerous circumferential suture techniques, including the running lock stitch, horizontal mattress, epitenon/intrafiber, and cross-stitch methods (Slide 9).

Size and type of suture
Studies have shown that large caliber sutures increase the strength of the repair.15 Although the use of 3-0 caliber suture has been advocated for increased tensile strengths, many surgeons use 4-0 caliber for flexor tendon repair.5 Larger suture caliber may increase the width of the repair and increase the work of flexion. A 3-0–caliber suture is generally reserved for repair of flexor tendons of larger width.

There is no definite answer as to what is the best suture material. Stainless steel has high tensile strength — an important characteristic of an ideal suture material, but stainless is very difficult to handle and loses much of its strength if kinked. Nylon and polypropylene monofilament have the disadvantage of having a low tensile strength, which may stretch and lead to increased gapping at the repair site. Braided polyester sutures offer the advantage of good strength, minimal elasticity, and easy handling, making this a popular choice among surgeons.

Number and placement of knots
The fewer the number of suture knots involved in the repair site the better because studies have shown that repairs usually rupture at the knots.16 Additionally, knots should be located outside the repair because they are generally stronger and less likely to interfere with tendon gliding.17 Finally, leaving a knot on the outer surface of the tendon should never be done because this can also interfere with tendon gliding.

Partial Laceration

Studies have shown that partial lacerations have significantly higher load and stiffness than a repaired tendon.18 In cases where the laceration is more than 60%, complications such as rupture or triggering are more common. Because of these findings, the current recommendation is that a partial tendon laceration involving 60% or more of the cross-sectional area of the tendon should be repaired according to standard techniques.5,19 Patients with a partial laceration of 60% or less are able to participate in the same rehabilitation program as patients with a complete laceration and repair.

Sheath Repair

There have been a number of conflicting studies on the risks and benefits of sheath repair. Despite the lack of clear data, many surgeons still advocate the repair of the tendon sheath. Benefits of repair include reduced adhesion formation, return of synovial nutrition, and better tendon mechanics.3 Repair can be technically demanding, however, and there is also the risk of making the repaired sheath too narrow and, as a result, restricting tendon movement.

Rehabilitation

Repaired flexor tendons were once treated postoperatively with immobilization to prevent rupture. This treatment, however, led to the formation of adhesions that prevent gliding of the tendon and leads to contractures and functional impairment.20 Postoperative mobilization breaks adhesions that may form, and numerous studies have confirmed the benefits of postoperative mobilization.21-23 Although early mobilization limits adhesion formation, it also has the potential to increase the risk of repair rupture because of forces placed on the tendon. Clinical studies of zone II repairs have shown rupture rates as high as 46%,23 with most being much lower.24

There have been conflicting reports about the amount of strength required for a repair to allow passive and active motion rehabilitation. Most studies generally refer to the work of Schuind. Schuind et al25 performed in vivo experiments to measure digital flexor tendon tensile strength. They described an average tensile load of 8.8 N in the flexor digitorum superficialis (FDS) during passive motion, and forces averaging 17 N with active pinch of the index finger. Based on Savage’s postulate that initial repair strength should be five times the average tendon load,12 an initial strength of at least 44 N is required for optimum FDS repair for passive motion and 85 N for active motion. In another analysis by Urbaniak, slightly different results were discovered with flexor digitorum profundus.26

Regardless of the exact numbers, techniques in modern flexor tendon repair are providing strong enough repairs to allow for protective passive and light active motion rehabilitation protocols, and the results have been good. At our institution, a dorsal blocking splint combined with early, protected passive and light active motion is used. The application of recent scientific discoveries has improved treatment and outcome of modern flexor tendon repair. Continued research will lead to even better techniques and improved results in the future.

References

  1. Bunnell S. Injuries of the hand. In: Surgery of the Hand. Philadelphia, Pa: JB Lippincott; 1944:449-502.
  2. Newmeyer WL 3rd, Manske PR. No man's land revisited: The primary flexor tendon repair controversy. J Hand Surg Am. 2004; 29:1-5.
  3. Strickland J. Development of flexor tendon surgery: Twenty-five years of progress. J Hand Surg Am. 2000; 25:214-235.
  4. Strickland J. Flexor tendon injuries: Foundations of treatment. J Am Acad Orthop Surg. 1995; 3:44-54.
  5. Boyer MI, Strickland JW, Engles D, Sachar K, Leversedge FJ. Flexor tendon repair and rehabilitation: State of the art in 2002. Instr Course Lect. 2003; 52:137-161.
  6. Aoki M, Manske PR, Pruitt DL, Kubota H, Larson BJ. Work of flexion after flexor tendon repair according to the placement of sutures. Clin Orthop. 1995; 320:205-210.
  7. Kessler I. The "grasping" technique for tendon repair. Hand. 1973; 5:253-255.
  8. McLarney E, Hoffman H, Wolfe SW. Biomechanical analysis of the cruciate four-strand flexor tendon repair. J Hand Surg Am. 1999; 24:295-301.
  9. Strickland JW. Flexor tendon injuries: Operative technique. J Am Acad Orthop Surg. 1995; 3:55-62.
  10. Becker H, Davidoff M. Eliminating the gap in flexor tendon surgery. A new method of suture. Hand. 1977; 9:306-311.
  11. Savage R, Risitano G. Flexor tendon repair using a "six strand" method of repair and early active mobilisation. J Hand Surg Br. 1989; 14:396-399.
  12. Savage R. In vitro studies of a new method of flexor tendon repair. J Hand Surg Br. 1985; 10:135-141.
  13. Su B. A tendon fixation device for flexor tendon repair. Part I: Biomechanical analysis. J Hand Surg Am. In process.
  14. Lotz JC, Hariharan JS, Diao E. Analytic model to predict the strength of tendon repairs. J Orthop Res. 1998; 16:399-405.
  15. Taras JS, Raphael JS, Marczyk SC, Bauerle WB. Evaluation of suture caliber in flexor tendon repair. J Hand Surg Am. 2001; 26:1100-1104.
  16. Trail IA, Powell ES, Noble J. An evaluation of suture materials used in tendon surgery. J Hand Surg Br. 1989; 14:422-427.
  17. Pruitt DL, Aoki M, Manske PR. Effect of suture knot location on tensile strength after flexor tendon repair. J Hand Surg Am. 1996; 21:969-973.
  18. Grewal R, Saw SS, Bastidas JA, Fischer KJ, Sotereanos DG. Passive and active rehabilitation for partial lacerations of the canine flexor digitorum profundus tendon in zone II. J Hand Surg Am. 1999; 24:743-750.
  19. McGeorge DD, Stilwell JH. Partial flexor tendon injuries: To repair or not. J Hand Surg Br. 1992; 17:176-177.
  20. Wang A, Gupta A. Early motion after flexor tendon surgery. Hand Clinics. 1996; 12:43-55.
  21. Lister G, Kleinert HE, Kutz JE, Atasoy E. Primary flexor tendon repair followed by immediate controlled mobilization. J Hand Surgery. 1977; 2:441-451.
  22. Baktir A, Turk CY, Kabak S, Sahin V, Kardas Y. Flexor tendon repair in zone 2 followed by early active mobilization. J Hand Surg Br. 1996; 21:624-628.
  23. Peck FH, Bucher CA, Watson JS, Roe A. A comparative study of two methods of controlled mobilization of flexor tendon repairs in zone 2. J Hand Surg Br. 1998; 23:41-45.
  24. Kitsis C, Wade PJ, Krikler SJ, Parsons NK, Nicholls LK. Controlled active motion following primary flexor tendon repair: A prospective study over 9 years. J Hand Surg Br. 1998; 23:344-349.
  25. Schuind F, Garcia-Elias M, Cooney WP 3rd, An KN. Flexor tendon forces: In vivo measurements. J Hand Surg Am. 1992; 17:291-298.
  26. Urbaniak J, Cahill J, Mortenson R. Tendon suturing methods: Analysis of tensile strength. In: American Academy of Orthopaedic Surgeons. Symposium on Tendon Surgery in the HandSt Louis, Mo: Mosby; 1975:70-80.