The Language of Bone Grafts and Bone Graft Substitutes
Three important terms are used when describing bone grafts and bone graft substitutes. An understanding of these three terms (osteogenesis, osteoconduction, and osteoinduction) is an essential prerequisite when discussing any bone graft substitute.
Osteogenesis refers to bone graft materials that provide live osteoblasts or stem cells that can differentiate into osteocytes. Autogenous bone grafts and bone marrow aspirates provide these cells and are referred to as osteogenic. To use a gardening analogy, these cells can be considered the "seeds for new bone."
Osteoconduction refers to bone graft materials that provide a three-dimensional structure or scaffold for bone ingrowth. Bone graft substitutes that mimic the architecture of cancellous bone have been developed. An optimal range of pore sizes seems to encourage the ingrowth of blood vessels, mesenchymal tissues, and osteoprogenitor cells.
Osteoinduction refers to the process where specific proteins signal host stem cells to differentiate into bone cells rather than into other types of tissue. These proteins are called bone morphogenic proteins (BMPs).
What Is Calcium Phosphate?
Caclium phosphate is a synthetic, resorbable cement that provides additional rigidity that augments internal fixation for fracture healing. The gradual resorption mimics the normal bone remodeling process.1 Calcium phosphate is an injectable paste of inorganic calcium and phosphate that hardens in situ and cures by a crystallization reaction to form dahllite, a carbonated apatite which is similar to that found in the mineral phase of bone.
Three forms of calcium phosphate are commercially available.2 Norian SRS (Skeletal Repair System, Synthes, Paoli, Pa) is available in the United States and Europe. BoneSource (Stryker Leibinger, Rutherford, NJ) has physical properties similar to Norian SRS and is available in the United States for craniofacial applications and in Europe for additional applications. Alpha-BSM (alpha bone substitute material, Depuy, Warsaw, Ind) is a calcium phosphate that has a lower compressive strength and a faster rate of resorption than Norian SRS.
Compared with cancellous bone grafts and other bone graft substitutes, calcium phosphate has a high compressive strength. For example, once Norian SRS hardens, approximately 12 hours after injection, its compressive strength is approximately 55 MPa. This is roughly 4 to 10 times greater than the average compressive strength of cancellous bone.
How Does Calcium Phosphate Work?
Because of its crystalline structure, calcium phosphate acts as an osteoconductive bone graft substitute. Calcium phosphate hardens to have a high compressive strength and may be useful in preventing subsequent displacement or depression of reduced articular fragments.
Animal studies have shown that the material is gradually remodeled in a manner that is qualitatively similar to normal bone remodeling. Over time, the calcium phosphate undergoes osteoclastic resorption followed by the invasion of small blood vessels that become surrounded by circumferential lamellae of new bone.3
What Are the Indications for the Use of Calcium Phosphate?
Calcium phosphate is indicated for filling bone voids or defects that are not intrinsic to the stability of the bone structure. It is contraindicated in areas where there is known infection. Calcium phosphate is indicated for use in conjunction with internal fixation implants. Its use in fractures of the distal radius, hip, tibial plateau, and calcaneus has been supported with both clinical studies and biomechanical investigations. Additional indications have been explored in recent preclinical studies.
Distal radius fractures
Several clinical studies have reported on the use of calcium sulfate in distal radius fractures.4,5 In one prospective study of 110 patients older than age 50 with distal radius fractures, patients were randomized to receive either closed reduction and cast immobilization for 6 weeks vs. closed reduction and percutaneous injection of calcium phosphate. Because of the stability provided by the calcium phosphate, the latter group was immobilized for only 2 weeks and then allowed to begin early wrist range of motion. The patients treated with calcium phosphate had less pain and earlier restoration of their motion. The results in the calcium phosphate group were rated favorably with a satisfactory result of 82%, compared to 56% in the control group. A higher incidence of malunions was found in the control group compared to the calcium phosphate group (42% vs. 18%).5
In another study, 323 patients with displaced distal radius fractures were randomized to receive conventional treatment or conventional treatment plus Norian SRS.6 As in the previous study, patients who received the Norian SRS injection were permitted to begin wrist range of motion at 2 weeks, while the other patients were maintained either in a cast or external fixator for 6 to 8 weeks. Patients who were treated with Norian SRS and permitted early wrist motion had significantly better function when evaluated 6 to 8 weeks postoperatively. This included better grip strength, wrist range of motion, and digital motion. However by 3 months' postoperative, only digital motion remained significantly better in the Norian SRS-treated patients, and at 1 year, no clinical differences were detected. The authors concluded that the use of Norian SRS may allow for accelerated rehabilitation following operatively managed distal radius fractures.
In a biomechanical study of simulated distal radius fractures, calcium phosphate was insufficient to withstand the physiologic loads associated with wrist flexion and extension unless supplemental K-wire fixation was added. Calcium phosphate combined with K-wire fixation was more stable than fixation with K-wires alone, but both were significantly less stable than external fixation that was augmented with calcium phosphate.7
Hip fractures
Calcium phosphate has been studied as adjunctive fixation in both femoral neck and intertrochanteric hip fractures.
Loss of reduction and fracture site collapse is common in osteoporotic femoral neck fractures, especially when screws are not optimally positioned to resist displacement. This leads to malunion, with alteration of gait and hip joint mechanics, and nonunion. Calcium phosphate has been studied to improve the fixation of osteoporotic femoral neck fractures. In one prospective clinical study, patients with displaced femoral neck fractures were randomized to undergo closed reduction and fixation with 2 cannulated screws with or without augmentation using Norian SRS around the screws. Using radiosteriometric analysis they showed significantly better early stability of the fracture site at 1 and 6 weeks.8 In a biomechanical investigation of simulated femoral neck fractures, specimens fixed with cannulated screws augmented with calcium phosphate resulted in significantly greater stiffness than fixation with cannulated screws alone.9
Many multifragmentary intertrochanteric hip fractures are at risk for displacement because of the loss of medial stability due to a separate posterolateral fracture fragment involving the lesser trochanter. In a biomechanical investigation of simulated unstable intertrochanteric hip fractures, specimens fixed with a sliding hip screw augmented with calcium phosphate had greater stiffness, stability, strength, and less shortening at the fracture site compared to those fixed with a sliding hip screw alone.1
Tibial plateau fractures
Calcium phosphate has also been used in depressed intra-articular tibial plateau fractures. In a study of 26 patients undergoing open reduction and internal fixation of displaced tibial plateau fractures, calcium phosphate was found to produce good outcomes. Because of the high mechanical strength of the cement, the authors allowed early weight bearing after a mean postoperative period of 4.5 weeks, with a range from 1 to 6 weeks. Despite early weight bearing, only 2 patients in this series suffered from a partial loss of reduction.8 In biomechanical studies of displaced tibial plateau fractures, calcium phosphate compared favorably to cancellous bone graft.10
Calcaneus fractures
Controversy remains concerning the relative benefits of operative vs. nonoperative treatment of calcaneus fractures. Restricted weight bearing for 8 to 12 weeks is recommended regardless of the treatment approach.
The rationale for the use of calcium sulfate in calcaneus fractures is to fill the void beneath the reduced posterior facet. This should potentially allow augmentation of the fixation and earlier weight bearing. Near the conclusion of one clinical series, patients were allowed to begin full weight bearing at 3 weeks and displayed no radiographic evidence of reduction loss.11 The effectiveness of calcium phosphate to resist deformation with cyclical loading in simulated calcaneal fractures has been confirmed in a biomechanical study.12
Vertebral fractures
Calcium phosphate has also been studied for possible use in painful osteoporotic vertebral compression fractures. Currently, vertebroplasty procedures use polymethylmethacrylate cement to restore the integrity of the vertebral body and provide pain relief. Calcium phosphate may provide the necessary biomechanical properties yet also allow subsequent bone remodeling. The use of calcium phosphate in conjunction with vertebroplasty is being explored in preclinical investigations.13
Other possible indications
Calcium phosphate may also serve as a potential growth factor delivery system. Calcium phosphate has been used successfully to deliver rhBMP-2 in a nonhuman primate fibular osteotomy model.14 In this model, the investigators examined several different carriers for the percutaneous administration of rhBMP-2 and found that a-bone substitute material (BSM) was the most promising. The investigators found that the gradual resorption of the a-BSM provided continued release of rhBMP-2 at the osteotomy site, offering prolonged bone growth stimulation.
Complications in the use of calcium phosphate
In a study of 20 patients who underwent curettage of enchondromas and injection with Norian SRS, 4 patients developed a painful soft tissue reaction. This prompted the authors to discontinue this method of enchondroma treatment and recommend that the cement be "sealed" by placing curetted bone over the exposed surface of the cement.15
Concerns have also been expressed about potential intra-articular extrusion of calcium phosphate when used in intra-articular fractures; however, when this has occurred, no reported adverse sequelae have been reported.6
References
- Elder S, Frankenburg EP, Goulet J. Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures. J Orthop Trauma. 2000; 14:386-393.
- Larsson S, Bauer TW. Use of injectable calcium phosphate cement for fracture fixation: A review. Clin Orthop. 2002; 395:23-32.
- Frankenburg EP, Goldstein SA, Bauer TW, et al. Biomechanical and histologic evaluation of calcium phosphate cement. J Bone Joint Surg Am. 1998; 80:1112-1124.
- Jupiter JB, Winters S, Sigman S, et al. Repair of five distal radius fractures with an investigational cancellous bone cement: A preliminary report. J Orthop Trauma. 1997; 11:110-116.
- Sanchez-Sotelo J, Munuera L, Madero R. Treatment of fractures of the distal radius with a remodellable bone cement: A prospective, randomized study using Norian SRS. J Bone Joint Surg Br. 2000; 82:856-863.
- Cassidy C, Jupiter JB, Cohen M, et al. Norian SRS cement compared with conventional fixation in distal radius fractures: A randomized study. J Bone Joint Surg Am. 2003; 85: 2127-2137.
- Higgins TF, Dodds SD, Wolfe SW. A biomechanical analysis of fixation of intra-articular distal radial fractures with calcium-phosphate bone cement. J Bone Joint Surg Am. 2002; 84:1579-1586.
- Mattsson P, Larsson S. Stability of internally fixed femoral neck fractures augmented with resorbable cement: A prospective randomized study using radiostereometry. Scand J Surg. 2003; 92:215-219.
- Stankewich CJ, Swiontkowski MF, Tencer AL, et al. Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement. J Orthop Res. 1996; 14:786-793.
- Yetkinler DN, McClellan RT, Reindel ES, et al. Biomechanical comparison of conventional open reduction and internal fixation versus calcium phosphate cement fixation of a central depressed tibial plateau fracture. J Orthop Trauma. 2001; 15:197-206.
- Schildhauer TA, Bauer TW, Josten C, Muhr H. Open reduction and internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures. J Orthop Trauma. 2000; 14:309-317.
- Thordarson DB, Hedman TP, Yetkinker DN. Superior compressive strength of a calcaneal fracture construct augmented with remodelable cancellous bone cement. J Bone Joint Surg Br. 1999; 81:239-246.
- Lim T-H, Brebaach GT, Renner SM, et al. Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine. 2002; 27:1297-1302.
- Seeherman HJ, Bouxsein M, Kim H, et al. Recombinant human bone morphogenetic protein-2 delivered in an injectable calcium phosphate paste accelerates osteotomy site healing in a nonhuman primate model. J Bone Joint Surg Am. 2004; 86:1961,1972.